Elevator button
Gomel Plant of Measuring Equipment has begun to produce Fittings switching "AK" to control the elevators of modern design, installed in residential buildings, public and private institutions, buildings, industrial enterprises increased reliability.
Valves installed directly in the lift and on the elevator platforms. The thickness of the panel, which can be installed fittings from 1 to 4 mm. Currently, the elevator button "AK" (fixture switching) comes "Plant Mogilevliftmach" for the acquisition of manufactured elevators.

ADVANTAGES:
1 Valves meet the requirements of TU BY 400002025.025-2008, GOST 12434 and kit shown in the table.
Dimensions and marking the installation of seats:
2 Valves to survive under the following working conditions:
3 Dimensions of fixtures no more than:
4 Weight fixtures not more than - 25 г.
5 Dip switches, used in the fixture ensure the normal operation when the switching voltage 24 V DC and a maximum switching current of 50 mA.
At the request of the customer armature AK1-05 can be equipped with microswitch, operating in a switching voltage of 220 V and 100 mA switching current.
6 Mechanical and switching durability of at least 10 6 clicks.
7 Enclosure protection IP 20 fittings in accordance with GOST 14254.
Valves installed directly in the lift and on the elevator platforms. The thickness of the panel, which can be installed fittings from 1 to 4 mm. Currently, the elevator button "AK" (fixture switching) comes "Plant Mogilevliftmach" for the acquisition of manufactured elevators.

ADVANTAGES:
- Vandal resistance and fire safety;
- Valves made from slow-burning materials;
- Low cost products compared to similar products of other companies.
1 Valves meet the requirements of TU BY 400002025.025-2008, GOST 12434 and kit shown in the table.
| Type elevator | Name of TU ВY 400002024.025-2008 | Design notation |
| Passenger elevators | LK1-01-Kr (Call / order) | VYAAL.6618.001 |
| LK1-01-3 (Call / order) | VYAAL.6618.002 | |
| LK1-01-C (Call / order) | VYAAL.6618.003 | |
| АК1-02 ( |
VYAAL.6618.004 | |
| АК1-03 (Cancel) | VYAAL.6618.005 | |
АК1-04 ( ) |
VYAAL.6618.014 | |
АК1-05 ( ) |
VYAAL.6618.012 | |
АК1-06 ( ) |
VYAAL.6618.013 | |
| AK1-01 KR Braille code (Order) | VYAAL.6618.015 | |
| Freight elevators | AK2-01-Kr (Call) | VYAAL.6618.007 |
| AK2-01-3 (Call) | VYAAL.6618.007 | |
| AK2-01-C (Call) | VYAAL.6618.007 | |
| AK2-02-Kr (Order) | VYAAL.6618.008 | |
| AK2-02-3 (Order) | VYAAL.6618.009 | |
| AK2-02-C (Order) | VYAAL.6618.010 | |
| АК2-03 (Cancel, |
VYAAL.6618.011 | |
АК1-04 ( ) |
VYAAL.6618.014 | |
АК1-05 ( ) |
VYAAL.6618.012 |
Dimensions and marking the installation of seats:
2 Valves to survive under the following working conditions:
- Ambient temperature from minus 30 ° C to plus 45 ° C;
- Atmospheric pressure 84 to 106,7 kPa (630 to 800 mm Hg);
- Relative humidity of ambient air at 125 ° C from 30% to 80%.
3 Dimensions of fixtures no more than:
- Height - 30 mm;
- Diameter -41 mm;
- Bore diameter - 32,5 mm.
4 Weight fixtures not more than - 25 г.
5 Dip switches, used in the fixture ensure the normal operation when the switching voltage 24 V DC and a maximum switching current of 50 mA.
At the request of the customer armature AK1-05 can be equipped with microswitch, operating in a switching voltage of 220 V and 100 mA switching current.
6 Mechanical and switching durability of at least 10 6 clicks.
7 Enclosure protection IP 20 fittings in accordance with GOST 14254.

)
)
)